File:IBM pSeries SPCN cabling examples.jpg: Difference between revisions

From RoggeWiki
Jump to navigation Jump to search
(SPCN3 is used to control and monitor the status of power and cooling within the I/O drawer. SPCN is a loop: Cabling starts from SPCN port 0 on the p5-570 to SPCN port 0 on the first I/O drawer. The loop is closed, connecting the SPCN port 1 of the I/O dra)
 
No edit summary
 
Line 13: Line 13:


Source: redp9117 - IBM System P5 570 Technical Overview and Introduction.
Source: redp9117 - IBM System P5 570 Technical Overview and Introduction.
[[Category:AIX]]

Latest revision as of 09:21, 12 April 2011

SPCN3 is used to control and monitor the status of power and cooling within the I/O drawer. SPCN is a loop: Cabling starts from SPCN port 0 on the p5-570 to SPCN port 0 on the first I/O drawer. The loop is closed, connecting the SPCN port 1 of the I/O drawer back to port 1 of the p5-570 system. If you have more than one I/O drawer, you continue the loop, connecting the next drawer (or drawers) with the same rule.

There are different SPCN cables to satisfy different length requirements: � SPCN cable drawer-to-drawer, 2 m (FC 6001) � SPCN cable drawer-to-drawer, 3 m (FC 6006) � SPCN cable rack-to-rack, 6 m (FC 6008) � SPCN cable rack-to-rack, 15 m (FC 6007) � SPCN cable rack-to-rack, 30 m (FC 6029)

Source: redp9117 - IBM System P5 570 Technical Overview and Introduction.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current09:20, 12 April 2011Thumbnail for version as of 09:20, 12 April 2011808 × 458 (51 KB)Tom (talk | contribs)SPCN3 is used to control and monitor the status of power and cooling within the I/O drawer. SPCN is a loop: Cabling starts from SPCN port 0 on the p5-570 to SPCN port 0 on the first I/O drawer. The loop is closed, connecting the SPCN port 1 of the I/O dra

There are no pages that use this file.